8075 Positive Displacement Batch Controller

Brand: Burkert Fluid Control Systems
Does not ship to OH, United States

This positive displacement flow batch controller with display is designed for use in slightly viscous fluid like glue, honey or oil. 

The batch controller is made up of a compact sensor fitting (S070) and an electronic module (SE35) quickly and easily connected together by a Quarter-Turn.
Features
  • Compact version for DN15 to DN100
  • Dosing
  • On site calibration by Teach-In
  • Check of input/output signals
  • Total and daily totalizers for batch quantity and number of batches, volume or mass totalizers displayed

Specifications

Accuracy

  • ± 0.5 % of Reading

Ambient Temperature Range

  • Operation & Storage (Version 115/230 Vac): -10° to 50° C (14° to 122° F)
  • Operation & Storage (Version 12-36 Vdc): -10° to 60° C (14° to 140° F)

Approvals & Certifications

  • Security: EN 61010-1
  • CE
  • EMC: EN 61000-6-2, EN 61000-6-3
  • UL (C,US): 61010-1 + CAN/CSA C22 No.61010-1

Cable Length

  • 164 feet (50 metres)

Circuit Protection

  • Protected Against Short Circuits

Consumption

  • Current with Sensor (without Consumption of Digital Input & Pulse Output): ≤ 45 mA at 36 Vdc with Relays
  • Current with Sensor (without Consumption of Digital Input & Pulse Output): ≤ 90 mA at 12 Vdc with Relays

Cover Material

  • Polycarbonate (PC)

Current

  • 125 mA - Max.

Diameter

  • Pipe: 1/2 to 4” (DN 15 to DN 100)

Display

  • 15 x 60 mm, 8-Digit LCD, Alphanumeric, 15-Segments, 9 mm High

Electrical Connectors

  • 1.5 mm², Max.
  • Cable Glands M20 x 1.5

Electrical Protection

  • Protected Against Overvoltage

Enclosure, Body Material

  • Polycarbonate (PC)

Environmental Protection

  • IP65

Flange Size - 1-1/2” (DN 40)

  • Unrated

Flange Size - 1” (DN 25)

  • Unrated

Flange Size - 2” (DN 50)

  • Unrated

Flange Size - 3” (DN 80)

  • Unrated

Flange Size - 4” (DN 100)

  • Unrated

Frequency

  • Output (Transistor): 0.6 to 2,200 Hz

Gland Material

  • Cable Glands: Polyamide (PA)

Humidity

  • ≤ 80 % Relative Humidity, Non-Condensing

Indication

  • LED

Input

  • DI (1 to 4) - Switching Threshold Voff: 2 Vdc, Max.
  • DI (1 to 4) - Switching Threshold Von: 5-36 Vdc

Input Impedance

  • 9.4 kiloohms

Materials of Construction

  • Front Panel Foil: Polyester
  • Lid: Polycarbonate (PC)

Measuring Range

  • Viscosity 5 MPa.s: 2 to 1,200 L/minute

Nut & Bolt Material

  • Nut: Polycarbonate (PC)

Output

  • Transistors (DO1 & DO4) - Line Drop: 2.7 Vdc at 100 mA
  • Transistors (DO1 & DO4): 100 mA - Max.
  • Transistors (DO1 & DO4): 5-36 Vdc

Power

  • 3 VA
  • Relay Output (Cutting Power): 750 VA, Max.

Power Supply

  • 115/230 Vac at 50/60 Hz
  • 12-36 Vdc, Max.

Pressure Range

  • bar: 0 to 55
  • kPa: 0 to 5,500
  • psi: 0 to 798

Process Temperature

  • Aluminum Body: 0° to 80° C (32° to 176° F)
  • Stainless Steel Body: 0° to 100° C (32° to 212° F)

Relay Output

  • DO2 & DO3, 230 Vac / 3 A (Resistive Load)
  • DO2 & DO3: 2 Relays (Normally Open)
  • DO2 & DO3: 40 Vdc / 3 A (Resistive Load)
  • UL Recognized: 30 Vac
  • UL Recognized: 42 V Peak, Max.
  • UL Recognized: 60 Vdc, Max.

Repeatability

  • ≤ 0.03 % of Reading

Reverse Polarity Protection

  • Protected Against Reverse Polarity

Screw Material

  • Stainless Steel

Seat / Seal Material

  • Seal: FEP
  • Seal: FKM
  • Seal: PTFE

Shaft Material

  • Stainless Steel

Shock

  • EN 60068-2-27

Supply Voltage

  • 27 Vdc Regulated

Switch Type

  • Transistor (NPN or PNP)

Vibration

  • EN 60068-2-6

Viscosity

  • 5 MPa·s
  • 1 Pa·s Max.

Wetted Materials

  • Rotor: PPS
  • Sensor Fitting, Rotor: 316F Stainless Steel (1.4401)
  • Sensor Fitting, Rotor: Aluminum

show more