Series MPM Dual Line Configurable Panel Meter

Brand: Dwyer Instruments, LLC

These 1/8 DIN digital panel meters accept signals from various transmitters and flowmeters and displays them on a six-digit, dual line display in engineering units.

These meters will also provide power to the field device and include a NEMA 4X front panel. Free, USB based programmnig sofware is resident on the meter. Options include up to four relays and a 4-20 mA output.

The Series MPM Dual Line Configurable Panel Meter is a general purpose process meter that is field selectable for a 4-20 mA or 0-10 V input signal. It provides 24 VDC to power the transmitter.

The dual line display can display the process variable on the upper line and engineering units on the lower line. 

Or, in dual scale mode, the process variable can be displayed in one units (like height) on the upper display and another (like volume) on the lower display. The meter also has an automatic Round Horizontal Tank function a well as 32 point linearization.
Features
  • Three levels of password protection
  • Math functions for flow & round horizontal tanks
  • 32-point linearization, square root or programmable exponent
  • Multi-pump alternation control
  • Rate displayed as units per second, minute, hour, or day
  • Total, grand total or non-resettable grand total
  • Two or four relays & isolated 4 to 20 mA output options
  • External 4-relay & digital I/O expansion modules
  • RS-232, RS-422/485 serial communication options

Specifications

Accuracy

  • ± 0.03 % of Calibrated Span ± 1 Count
  • 10 % to 100 % of Calibrated Span

Approvals & Certifications

  • CE
  • UL

Consumption

  • 100 mA at 24 Vdc
  • 12-24 Vdc
  • 200 mA at 24 Vdc
  • 40 mA at 24 Vdc
  • 85-265 Vac

Display

  • 0.46”
  • 0.60” (15.2 mm)
  • Dual-Line 6-Digit Display

Electrical Connectors

  • Removable Screw Terminal Blocks Accept 12 to 22 AWG Wire

Electrical Rating

  • 1/14 hp at 125/250 Vac Inductive
  • 3 A at 25/250 Vac Resistive
  • 3 A at 30 Vdc Resistive

Environmental Protection

  • IP65
  • NEMA 4X

Input

  • ± 10 V
  • 0-20 mA
  • 0-5 V
  • 4-20 mA

Input Impedance

  • 50 to 100 ohms

Operating Temperature

  • -40° to 65° C (-40° to 150° F)

Output

  • 4-20 mA

Power Requirement

  • 12 to 24 Vdc ± 10 %
  • 15 W, Max.
  • 20 W, Max.
  • 85-265 Vac 50/60 Hz
  • 90-265 Vdc

Response Time

  • 0 to 1000 seconds

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Switch Type

  • 2 or 4 SPDT (Form C) Internal or 4 SPST (Form A) External

  • Level Monitoring
  • Pump Control
  • Flow Rate Indication
  • Flow Totalization
  • Open Channel Flow Monitoring
  • Process Control

show more