Price
Request a Quote
Stock
Out of Stock

Specifications

Brand

Accuracy

  • ± 0.10 % of Span (± 0.25 with Field-Selectable Option)

Adjustment Type

  • Factory Set (Pre-Set)
  • Field Adjustable

Approvals & Certifications

  • ATEX
  • CE
  • CSA
  • FM

Circuit Protection

  • EMI/RFI Protected
  • Reverse Polarity

Consumption

  • 3.0 scfh (0.11 m³/hour) at Mid Range

Deadband, Approximate

  • 0.02 % of Span

Elastomers

  • Buna-N

Electrical Connectors

  • 1/2” NPT
  • M20 x 1.5

Enclosure Finish

  • Epoxy Powder-Coated

Enclosure, Body Material

  • Chromate Treated Aluminum

Environmental Protection

  • IP65
  • NEMA 4X / IP65

Flow Rate

  • 12.0 SFCM (20.0 m³/hour) at psig: 100 (bar: 7.0, kPa: 700) Supply
  • 4.5 SFCM (7.6 m³/hour) at psig: 25 (bar: 1.7, kPa: 170) Supply

Hysteresis

  • ± 0.10 % of Span (± 0.25 with Field-Selectable Option)

Input

  • 4-20 mA

Mounting

  • 2” (50.8 mm) Pipe
  • Direct Wall
  • Panel

NPT Connection

  • 1/4” NPT Female

Operating Temperature

  • -40° to 71° C (-40° to 160° F)

Operating Voltages

  • 9.5 Vdc @ 20 mA

Output Pressure

  • bar: 0.20 to 2.00
  • kPa: 20.68 to 206.8
  • psig: 3 to 30

Position Effect

  • No Measurable Effect

Relief

  • Relieving

Repeatability

  • ± 0.10 % of Span (± 0.25 with Field-Selectable Option)

RFI/EMI Effect

  • < 0.5 % of Span Change in Output Pressure

Storage Temperature

  • -40° to 93° C (-40° to 200° F)

Supply Pressure

  • psig: 100 (bar: 7, kPa: 700)

Supply Pressure Effect

  • No Measurable Effect

Temperature Effect

  • ± 0.045 % °F (0.07 % °C) of Span

Trim Material

  • Brass
  • Stainless Steel
  • Zinc-Plated Steel

Vent

  • Straight
  • Tapped Exhaust

Vibration Effect

  • < ± 1.0 % of Span Under the Following Conditions: 5 to 15 Hz at 0.8” Constant Displacement, 15 to 500 Hz at 10 G’s

Documentation

show more