Versa-Switch Model VS5100

Brand: DELTA M Corporation

  • Simple field adjustable thermal differential switch for mass flow, level, and/or temperature of liquids or gasses with time delay adjustable from 0 to 300 sec.
  • Wide operating temperature range -100° to 850° F (-70° to 458° C).
  • User configurable operating power 110Vac, 220Vac, or 24Vdc.
  • Removable, plug in electronics.
  • Can be configured with 2 independent outputs, such as level or mass flow with temperature or two mass flow rates.
  • Level response time of .1 to 1 second on wetting, media dependent
  • Flow response time of .5 to 10 seconds, media dependent
  • Can be used for either gas or liquid applications including interface detection.
  • Self heating sensor design improves repeatability. No separate heater to fail or slow response time.

Models

Models

Process Connection

Process Connection

Sensor Material

Sensor Material

Insertion 'U' Length

Insertion 'U' Length

Power

Power

Configuration

Configuration

Calibration

Calibration

Process Connection Configuration

Process Connection Configuration

Display & Interface Options

Display & Interface Options

Retractable Packing Gland

Retractable Packing Gland

Live Tap

Live Tap

Housing

Housing

Alarm Configurations

Alarm Configurations

Temperature Options

Temperature Options

Output

Output

Cable

Cable

Tag

Tag

Options

Options
Part Number / SKU

VS5100-075-S6-2.000-FLD-LE-00

  • Models

    Dual Channel - CSA Approved

  • Process Connection

    3/4” Male NPT

  • Sensor Material

    316L Stainless Steel

  • Insertion 'U' Length

    Length in Inches

  • Power

    Field Configuring

  • Configuration

    Local Electronics

  • Calibration

    No Factory Calibration

  • Process Connection Configuration

    Without Extended Neck

  • Display & Interface Options

    Standard

  • Retractable Packing Gland

    No Variable Insertion

  • Live Tap

    Fixed Tap

  • Housing

    Single Sided

  • Alarm Configurations

    No Alarm

  • Temperature Options

    Standard Temperature

  • Output

    DPDT

  • Cable

    No Additional Cable

  • Tag

    No Tag

  • Options

    Standard Options

Specifications

Alarm

  • Continuous Monitoring Circuit to Alarm Should a Failure Condition of any Sensor, Component, Wiring, or Power Occur

Approvals & Certifications

  • CSA - Class I, Div. 1, Groups B,C, & D & Class II, Div. 1, E, F & G with T4A Temp Rating.
  • FM
  • UL

Electrical Rating

  • 5 A at 240 Vac

Enclosure, Body Material

  • 316L Stainless Steel
  • Hastelloy
  • Inconel
  • Monel
  • Other Exotic Materials

Environmental Protection

  • Explosion-proof
  • IP54
  • IP66
  • NEMA 3, 4, 4X, 7, 9 / IP54, 66
  • NEMA 4
  • NEMA 4X
  • NEMA 7
  • NEMA 9

Flange Size - 1” (DN 25)

  • 1" (DN 25) - 150#
  • 1" (DN 25) - 300#

Flange Size - 2” (DN 50)

  • 2" (DN 50) - 150#
  • 2" (DN 50) - 300#

Flow Rate

  • Gas: 0.1 to 500 FPS
  • Liquid: 0.01 to 5.0 FPS

Insertion 'U' Length

  • 0.5" (1.27 cm)
  • 2" (5 cm)

Length

  • Insertion Option: ≥ 0.5"
  • Insertion Standard: 2.0"

NPT Connection

  • 1" NPT Male
  • 1/2" NPT Male
  • 3/4" NPT Male

Operating Temperature - Electronics

  • -40° to 60° C (-40° to 140° F)

Operating Temperature - Sensor

  • -70° to 458° C (-100° to 850° F)

Power Requirement

  • 110 Vac
  • 220 Vac
  • 24 Vac
  • 24 Vdc

Pressure Range

  • psia: 3,000 (bar: 207, kPa: 20,684)

Principle of Operation

  • Thermal, Calorimetric

Process Connection - Other

  • Low Flow Sensor
  • SP76 Sensor

Response Time

  • Media Dependent 0.5 to 10 seconds

Sensor, Probe Type

  • Dual RTD Sensors
  • Thermal Differential

Switch Type

  • DPDT
  • SPDT

Tri-Clamp Connection

  • 1-1/2" Sanitary with 3A Stamp

show more