Series 2700 & 2800 Current to Pressure Transducer

Brand: Dwyer Instruments, LLC

The Series 2700 current to Pressure Transducer combines economical startup cost, low air consumption, and reliable performance to make the 2700 a great investment.

The unit converts a variable current signal to a proportional pneumatic output. It has input and output ports on both the front and back which allows for versatile plumbing. The NEMA 4X enclosure enables the unit to be installed indoors or outdoors, however, the unit is not vibration resistant.

It is FM and CSA approved for intrinsically safe operation. 

The 2700 is designed for remote or panel mounting. An integral volume booster provides high flow capacity, increasing control speed in critical applications. Other features include external zero and span adjustments which are convenient for field calibration. 

The Series 2800 current to Pressure Transducer utilizes a closed loop pressure feedback system that closely controls output and compensates for vibration, mounting angle, temperature, and supply pressure variations.

These characteristics make this unit ideal for field mounting on a valve. The control mechanism is a piezoceramic actuator encapsulated in a protective skin, which provides a constant defense against humidity and contaminants. These features make this unit ideal for use in demanding applications. 

The 2800 also comes in a NEMA 4X enclosure and is field reversible. It is FM and CSA approved intrinsically safe, as well. For ease of installation, this model has input and output ports on both the front and back and can be easily panel mounted.
Features
  • NEMA 4X enclosure
  • FM and CSA approved for intrinsically safe
  • Vibration and position insensitive (2700)
  • Input and output ports on front and back (2700)
  • Vibration and position insensitive (2800)
  • Input and output ports on front and back (2800)

Specifications

Accessories

  • Valve Mounting Bracket

Accuracy

  • ± 0.1 % of Span

Air Consumption

  • 0.025 to 0.03 scfm (0.036 m³/hour) at Midrange Typical

Approvals & Certifications

  • CE
  • CSA
  • FM

Deadband

  • 0.02 % of Span

Electrical Connectors

  • 1/2” NPT Female

Enclosure, Body Material

  • Chromate - Treated Aluminum with Epoxy Paint

Environmental Protection

  • Class I, Div. 2, Groups A, B, C & D
  • Class I, II, & III, Div. 1, Groups C, D, E, F, G
  • Class I, II, & III, Div. 2, Groups A, B, C, D, F, G
  • Class I, Zone 0, Group IIB
  • Class II, Div. 2, Groups F & G, Class III
  • Intrinsically Safe
  • IP66
  • NEMA 4X

Filter

  • 40 microns

Flow Capacity

  • 4.5 to 12 scfm (7.56 to 20.52 m³/hour) at psig: 25 to 100 (kPa: 170 to 690, bar: 1.7 to 6.9) - Output Capacity

Hysteresis

  • < 0.5 % of Span
  • ± 0.1 % of Span

Input Signal

  • 4-20 mA

Linearization

  • < ± 0.5 % of Span

Media

  • Clean Dry Air Filtered to 40 microns
  • Oil Free

Mounting

  • 2” (50.8 mm) Pipe Mounting Kit
  • DIN Rail Mounting
  • Pipe Mounting Kit

NPT Connection

  • 1/4” NPT Female - Pressure Connection

Operating Temperature

  • -40° to 71° C (-40° to 160° F)

Output

  • psig: 3 to 30 (kPa: 20.7 to 206.8, bar: 0.2 to 2.1)

Power Requirement

  • Loop Powered

Pressure Range

  • bar: 0.3 to 6.9
  • kPa: 34.5 to 700
  • psig: 5 to 100

Repeatability

  • < 0.5 % of Span
  • ± 0.1 % of Span

Sensitivity

  • < 0.1 % of Span Per psig: 1 (kPa: 100, bar: 0.1) - Supply Pressure Sensitivity

Storage Temperature

  • -40° to 93° C (-40° to 200° F)

Supply Pressure

  • psig: 5 to 100 (kPa: 34.47 to 689.5, bar: 0.3 to 6.9) - Air Supply

Temperature Range

  • -29° to 66° C (-20° to 150° F)

  • Controlling valve actuators, pneumatic valve positioners, air cylinders, clutches, brakes, dampers, louvers and pumps

show more