8719 Liquid Flow Controller

Brand: Burkert Fluid Control Systems
Does not ship to VA, United States

Type 8719 is an instrument for liquid flow control in process technology. The measured value provided by the sensor will be compared in the digital control electronics with the predefi ned set point according to the signal; if a control difference is present, the control value output to the proportional valve will be modified using a PI-control algorithm. 

In this way, the flow can be maintained at a fixed value or a predefined profile can be followed, regardless of pressure changes or other disturbances in the system. 

As a control element, a proportional valve working at low friction guarantees the high sensitivity and good control characteristics of the unit. MassFlowCommunicator software can be used for parameterisation and diagnosis.

Specifications

Accuracy

  • ± 0.5 % of Full Scale
  • ± 1.5 % of Reading

Ambient Temperature Range

  • 0° to 55° C (32° to 131° F)

Applications

  • Bio Reactors
  • Fuel Cell Technology
  • Heat Treatment
  • Machine Tools
  • Material Coatings
  • Packaging Technology

BSP Connection

  • G 1/4” Female
  • G 1/8” Female

Communication

  • DeviceNet Bus
  • Digital
  • FOUNDATION Fieldbus, CAN Open
  • PROFIBUS DP

Consumption

  • Power Consumption: 10 W with Fieldbus Version
  • Power Consumption: 7.5 W

Electrical Connectors

  • 5-Pin M12, Socket or Plug with Fieldbus
  • 8-Pin Round Connector Socket
  • D-Sub 15-Pin Connector

Electrical Contacts

  • Normally Closed
  • Normally Open

Enclosure, Body Material

  • PBT
  • Stainless Steel

Environmental Protection

  • Protection Class: IP65

Flow Rate

  • Full Scale Range: 0.015 to 0.6 LPM Water
  • Full Scale Range: 0.9 to 36 I/h

Indication

  • LED Indication for Power, Communication, Limit & Error

Input Impedance

  • 20 kiloohms (Voltage)

Input Signal

  • 0-10 V
  • 0-20 mA
  • 0-5 V
  • 4-20 mA

Media

  • Clean & Low Viscous Liquids
  • Water

Mounting Position

  • Horizontal
  • Vertical

NPT Connection

  • 1/4” NPT Female
  • 1/8” NPT Female

Operating Pressure

  • Maximum
  • Typical, Max.

Operating Voltages

  • 24 Vdc ± 10 %

Output

  • 0-10 V, Actual Value
  • 0-20 mA (Actual Value)
  • 0-5 V, Actual Value
  • 4-20 mA (Actual Value)
  • Burden Current Output: 600 ohms, Max.
  • Maximum

Process Temperature

  • 10° to 40° C (50° to 104° F)

Relay Output

  • Two Relay Outputs: 1 A at 60 V, 60 VA

Repeatability

  • ± 0.5 % of Full Scale

Response Time

  • Settling Time (t95 %): < 500 milliseconds

Seat / Seal Material

  • Seal: EPDM
  • Seal: FFKM
  • Seal: FKM

Sensor Circuit

  • Residual Ripple: < 2 %

Sensor, Probe Type

  • Differential Pressure

Turndown

  • 1:10

Viscosity

  • 0.4 to 4 cSt

  • Heat treatment
  • Machine tools
  • Fuel cell technology
  • Packaging technology
  • Material coating,
  • Bio reactors

show more