6013 Direct-Acting 2/2-Way Plunger Valve

Brand: Burkert Fluid Control Systems
Does not ship to Massachusetts, United States

Valve 6013 is a direct-acting plunger valve. The stopper and plunger guiding tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the application.

A Burkert-specific flange design (SFB) enables space-saving arrangement of valves on a manifold. The coils are moulded with polyamide or with chemically resistant epoxy. Pulse coils and ‘Kick and Drop’ electronics are available for overexcitation (plug 2511) for the reduction of electrical power consumption during operation.

Optional manual actuation enables quick commissioning and easy maintenance.

In combination with a plug in accordance with DIN EN 17301-803 Form A, the valves satisfy protection class IP65. Stainless steel valves satisfy NEMA 4X.
Features
  • Direct-acting and compact valve up to diameter of DN 6
  • Vibration-proof, bolted coil system
  • Increased leak-tightness with welded plunger guiding tube
  • Explosion proof versions
  • Energy-saving pulse versions

Specifications

Ambient Temperature Range

  • Maximum

Approvals & Certifications

  • CSA-EX Div. 1/2 European Gas Approval Class A, Group 2
  • FM
  • IECEx PTB 14.0049 x Ex Mb IIC T4 Gb Ex Mb IIIC T135° C (275° F) Db, IECEx EPS 16.0021 x Ex Eb Mb IIC T4 Gb Ex Mb Tb IIIC T130° C (266° F) Db
  • PTB 14-ATEX-2023 x II 2 G Ex Mb IIC T4 Gb II 2D Ex Mb IIIC T135° C (275° F) Db, EPS 16-ATEX-1046 x II 2 G Ex Eb Mb IIC T4 Gb II 2D Ex Mb Tb IIIC T130° C (266° F) Db
  • UL
  • UR

BSP Connection

  • G 1/4” Female
  • G 1/8” Female
  • G 3/8” Female - Model 6013
  • 1/4” BSPT Female
  • 1/8” BSPT Female
  • 3/8” BSPT Female

Cable Length

  • Moulded Cable: 9.842 feet (3 metres) - ATEX/IECEx Version

Cable Material

  • Cable: Polyolefin Copolymer Electron Beam Crosslinked - ATEX/IECEx Cable Version

Consumption

  • Power Consumption: 10 W AC or DC (11) - Circuit Function A
  • Power Consumption: 7 W AC - Circuit Function B
  • Power Consumption: 8 W AC or DC (9) - Circuit Function A

Cover Material

  • Polyamide

Duty Cycle

  • Duty Cycle / Single Valve (with Block Assembly on Manifold): 100 % Continuous Rating Intermittent Operation 60 % (30 minutes) or with 5 W Coil on Request

Electrical Connectors

  • M20 x 1.5
  • Tag Connector According to DIN EN 175301-803 Form A for Cable Plug Typical 2508

Electrical Contacts

  • Normally Closed
  • Normally Open

Enclosure, Body Material

  • 303 Stainless Steel, 1.4305
  • Brass

Environmental Protection

  • Explosion-proof
  • IP65 with Cable Plug
  • IP66
  • IP68
  • NEMA 4X
  • Vibration-Proof

Flow Rate

  • Water: 0.08 to 0.55 Kv (m³/hour)

Insulation

  • Coil Insulation: Epoxy Class H
  • Coil Insulation: Polyamide Class B

Materials of Construction

  • Armature Guide Tube: 305 Stainless Steel, 1.4303
  • Coil: Epoxy - High Temperature Version
  • Coil: Polyamide (PP)
  • Junction Box: Aluminum - ATEX/IECEx Junction Box Version
  • Magnetic Core, Stopper: 430FR Stainless Steel (1.4105)
  • Sub-Base: 304 Stainless Steel, 1.4301 Surface Thick Film Passivated

Media

  • Neutral Gases & Liquids (Compressed Air, Water, Hydraulic Oil) - Model 6013
  • Neutral Medium, Which Does Not Attack the Body & Seal Materials - Model 6013 A
  • Technical Vacuum - Model 6013

Mounting

  • Manifold

Mounting Position

  • Preferably with Actuator Upright

NPT Connection

  • 1/4” NPT Female
  • 1/8” NPT Female
  • 3/8” NPT Female

Nut & Bolt Material

  • Locknut: 303 Stainless Steel, 1.4305 - Stainless Steel Version
  • Locknut: PTFE - Stainless Steel Version
  • Locknut: Stainless Steel (Surface Finish Thick Film Passivated) - Brass Version

Operating Voltages

  • 230 V / 50 Hz - Model 6013 A
  • 24 Vdc
  • 24-230 V / 50 Hz - Model 6013

Orifice Size

  • 0.059” to 0.236” (1.5 to 6 mm)

Plug Material

  • Cable Plug: Polyamide (PP)

Power

  • Coil Effective Power: 7-10 W
  • Electrical Power (Hold): 17 VA (AC) - Circuit Function B
  • Electrical Power (Hold): 17-22 VA (AC) - Circuit Function A
  • Electrical Power (Inrush): 24 VA (AC) - Circuit Function B
  • Electrical Power (Inrush): 24-30 VA (AC) - Circuit Function A

Pressure Range

  • psi: 0 to 362.6 (kPa: 0 to 2,500, bar: 0 to 25)

Process Temperature

  • FKM, Circuit Function B (AC): -10° to 100° C (14° to 212° F) PA Coil Till 120° C (248° F) Epoxy Coil
  • FKM, Circuit Function B (DC): -10° to 120° C (14° to 248° F)
  • PTFE / Graphite: -40° to 180° C (-40° to 356° F)

Response Time

  • Closing: 30 milliseconds
  • Opening: 20 milliseconds

Ring Material

  • Shading Ring: Copper (Cu) - Brass Version
  • Shading Ring: Silver (AG) - Stainless Steel Version

Seat / Seal Material

  • Armature Seal: FKM
  • Armature Seal: PTFE - High Temperature Version
  • Flat Seal: NBR
  • Seal: EPDM
  • Seal: Graphite - High Temperature Version

Size

  • Coil Size: 1.259” (32 mm) - Circuit Function B
  • Coil Size: 1.259” to 1.574” (32 to 40 mm) - Circuit Function A

Solenoid Type

  • 2/2-Way

Spring Material

  • 301 Stainless Steel, 1.4310

Tolerance

  • Voltage Tolerance: ± 10 %

Viscosity

  • Maximum

show more