8041 Electromagnetic Flow Transmitter

Brand: Burkert Fluid Control Systems
Does not ship to Massachusetts, United States

The electromagnetic flow transmitter 8041 has been designed for pipes with diameters ranging from 1/4" to 16" and liquids having a conductivity > 20 µS/cm.

The transmitter is a magmeter made up of an electronic module and a sensor which armature is in PVDF or stainless steel. It is fitted with a 4-20 mA output, a pulse rate output and a relay output.

The different parameters can be programmed by means of 5 switches, a push-button and a 10 led bargraph. The version with a stainless steel sensor can be used in applications with higher pressures (232 psi) and higher temperatures 150° C (302° F).
Features
  • Sensor in solid state technology
  • Working as a transmitter and/or as an On/Off controller
  • Automatic-calibration of full scale: Teach-In
  • Clean in place (CIP)
  • FDA approved

Specifications

Accuracy

  • Standard K-factor: ≤ ± 4 % of Reading
  • Teach-In: ≤ ± 2 % of Reading

Alarm

  • Fault Signalling: 22 mA at 0 Hz
  • Full Scale Exceeding: 22 mA at 256 Hz

Ambient Temperature Range

  • Operating: -10° to 60° C (14° to 140° F)

Applications

  • Flow Control of Drinking Water (FDA Approval)
  • Food Processing Industry: Monitoring of the Cleaning Cycles (FDA Approval)
  • Irrigation
  • Laundries: Measurement & Control of the Water Consumption
  • Swimming Pools: Pump Protection & Flow Control
  • Wastewater Treatment

Approvals & Certifications

  • Security: EN 61010-1
  • CE
  • EMC 89/336/EC, EN 50081-1, EN 61000-6-2
  • FDA
  • LVD 73/23/EC

Conductivity

  • 20 µS/cm Min.

Consumption

  • Current Consumption: ≤ 220 mA

Cover Material

  • PVDF Sensor Version: Polycarbonate (PC) (Glass Fibre Reinforced)
  • Stainless Steel Sensor Version: Polyphthalamide (PPA) (Glass Fibre Reinforced)

Diameter

  • Pipe: 1/4 to 16” (DN06 to DN 400)

Duty Cycle

  • 50 % ± 1 %, 100 mA - Max.

Electrical Connectors

  • 2, 3 & 5 Cable Glands
  • Cable Glands M20 x 1.5 (0.75 mm²) Cross-section, Shielded
  • Remote Electronics: Terminal Strip

Electrical Contacts

  • Normally Closed
  • Normally Open

Electrical Protection

  • Reversed Polarity of DC

Enclosure, Body Material

  • PVDF Sensor Version: Polycarbonate (PC) (Glass Fibre Reinforced)
  • Stainless Steel Sensor Version: Polyphthalamide (PPA) (Glass Fibre Reinforced)

Environmental Protection

  • IP65

Flow Rate

  • 20,000 gpm (100,000 L/minute, 5,000 m³/hour)

Frequency

  • 0 to 240 Hz

Gasket Material

  • FKM (FDA Agreements)

Gland Material

  • Cable Glands: Polyamide (PA)

Humidity

  • < 80 % Relative Humidity, Non-Condensated

Linearity

  • ≤ ± (1 % of Reading + 0.1 % of Full Scale)

Loop Impedance

  • Signal Current: 1,100 ohms at 36 Vdc, Max.
  • Signal Current: 330 ohms at 18 Vdc, Max.

Measuring Range

  • 0.7 to 32.8 feet/sec (0.2 to 10 m/sec)

Nut & Bolt Material

  • Nut (PVDF Sensor Version): Polycarbonate (PC) (Glass Fibre Reinforced)
  • Nut (Stainless Steel Sensor Version): Polyphthalamide (PPA) (Glass Fibre Reinforced)

Output

  • Signal Current: 4-20 mA, 100 milliseconds Refresh Rate

Pipe Size

  • 1/4” to 16”

Power Supply

  • 18-36 Vdc Filtered & Regulated (3-Wires)

Pressure Range

  • bar: 0 to 16
  • kPa: 0 to 1,600
  • psi: 0 to 232

Process Temperature

  • Fluid Temperature (PVDF Sensor Version): 0° to 80° C (32° to 176° F)
  • Fluid Temperature (Stainless Steel Sensor Version): -15° to 150° C (5° to 302° F)

Relay Output

  • 3 A at 250 Vac

Repeatability

  • ≤ 0.25 % of Reading

Ring Material

  • Earth Ring (PVDF Sensor Version): 316L Stainless Steel, 1.4404

Screw Material

  • Stainless Steel

Seat / Seal Material

  • Seal: EPDM

Sensor, Probe Material

  • Sensor: Metal
  • Sensor: Polypropylene (PP)
  • Sensor: PVC
  • Sensor: Stainless Steel

Shock

  • EN 60068-2-27

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

Supply Voltage

  • Remote Electronics: 115-230 Vac
  • Remote Electronics: 18-30 Vdc

Temperature Range

  • PVDF Sensor Version: -17.7° to 70° C (0° to 158° F)
  • Stainless Steel Sensor Version: -17.7° to 150° C (0° to 302° F)

Tri-Clamp Connection

  • 1” Tri-Clamp
  • 1-1/2” Tri-Clamp
  • 1-1/4” Tri-Clamp
  • 2” Tri-Clamp
  • 2-1/2” Tri-Clamp
  • 3/4” Tri-Clamp

Vibration

  • EN 60068-2-6

Welded Connection

  • 1” Weld End
  • 1-1/2” Weld End
  • 1-1/4” Weld End
  • 2” Weld End
  • 2-1/2” Weld End
  • 3/4” Weld End

Wetted Materials

  • Electrode Holder (Stainless Steel Sensor Version): PEEK (FDA Agreements)
  • Sensor Armature & Electrodes: 316L Stainless Steel, 1.4404
  • Sensor Armature: PVDF

  • Waste water treatment
  • Flow control of drinking water (FDA approval)
  • Laundries: measurement and control of the water consumption
  • Swimming pools: pump protection and flow control
  • Food-processing industry: monitoring of the cleaning cycles (FDA approval)
  • Irrigation

show more