Adjustment Type
- Captive Clamp Screws
- Factory Set (Pre-Set)
- Set Point Adjustment
Ambient Temperature Range
- -40° to 71° C (-40° to 160° F)
Applications
- Chemical & Petrochemical
- Midstream & Downstream Oil & Gas
- Pharmaceutical Plants
- Pulp & Paper Mills
- Steel & Aluminum Mills
- Wastewater Treatment Plants
Approvals & Certifications
Approvals & Certifications
- ATEX Directive (94/9/EC) II 1 G EEx ia IIC T6 Ga Tamb: -50° to 60° C (-58° to 140° F)
- CE
- CPT 0ExiaIICT6 Tamb: -50° to 60° C (-58° to 140° F)
- CRN
- CSA C22.2 No. 14 & 213 - File # E40857
- GOST-R 51330.0, 51330.1, 51330.10 & 51330.14
- Low Voltage Directive (LVD) 73/23/EC & 93/68/EEC
- PED: 97/23/EC
- UL (C,US) 508 & 1604, Class I, Div. 2, Grade A, B, C, D, Class II, Div. 2, Group F, G, Class III
Deadband
- psi: 3 to 66 (kPa: 20.7 to 455.1, bar: 0.2 to 4.6)
- Temperature Deadband: Typically 4 % of Range Under Laboratory Conditions (21.11° C (70° F) Ambient Circulating Bath at Rate of 0.5° F Per Minute Change)
Electrical Connectors
- 1/2” NPT Female
- 7/8” Diameter Knockout
- 7/8” Hole to 1/2” NPT Female Watertight Conduit Fitting
- Common
Electrical Contacts
- Normally Closed
- Normally Open
- Switch Contacts Gold Flashed
Electrical Rating
- 0.5 A at 125 Vdc
- 1 A at 48 Vdc
- 11 A at 125/250 Vac Resistive
- 5 A at 28 Vdc
Enclosure, Body Material
- Gasketed Die Cast Aluminum
Environmental Protection
- Intrinsically Safe
- IP66
- NEMA 4X
- NEMA 7
- NEMA 9
Flange Type
- 1” Lap Joint
- Raised Face (RF)
Mounting
- 1.5” Flush Mount
- Pipe
- Surface
Name Plate, Tag Material
- Anodized Aluminum
- Stainless Steel, Paper ID Tag & Wire Attachment
Overpressure & Static Pressure Limits
- Over Range Pressure - psi: 1,000 (kPa: 6,895, bar: 68.9)
Process Connection Material
Proof Pressure
- psi: 1,500 (kPa: 10,340, bar: 103.4)
Repeatability
- Set Point Repeatability: ± 1.5 % of Adjustable Range
Service
- Oxygen Service Cleaning, Alcohol Cleaning to Remove Residue from the Process Connection
Set Point - Decreasing
- bar: 0.3 to 20.7
- kPa: 34.5 to 2,068
- psi: 5 to 300
Set Point - Increasing
- bar: 0.3 to 20.7
- kPa: 34.5 to 2,068
- psi: 5 to 300
Shock
- Set Point Repeats after 15 G, 10 millisecond Duration
Storage Temperature
- -54° to 71° C (-65° to 160° F)
System Pressure
- bar: 0 to 68.9
- kPa: 0 to 6,895
- psi: 0 to 1,000
Vibration
- Set Point Repeats after 2.5 G, 5 to 500 Hz