Adjustment Type
- Factory Set (Pre-Set) One Switch
Ambient Temperature Range
- -40° to 71° C (-40° to 160° F)
Applications
- Anesthesia Equipment
- OEM Applications
- Plasma Cutting
- Sterilizers
Approvals & Certifications
- CE
- CSA C22.2 No. 14, File # E42272
- Low Voltage Directive (LVD) 2006/95/EC
- PED: 97/23/EC
- UEC Compliant to LVD
- UL (C,US) 508
Approvals & Certifications
Deadband
- Inches Hg: -1 to -2.5
- psi: 0.491 to 1.228 (kPa: 3.39 to 8.47, Mbar: 33.9 to 84.7)
Electrical Connectors
- Direct to Switch Terminals
Electrical Contacts
- Gold Contacts, 1 A at 125 Vac Resistive
- Normally Closed
- Normally Open
Electrical Rating
- 1 A at 125 Vac Resistive
- 10 A 125 Vdc or Vac Resistive, Deadband & Min. Set Point Will Increase
- Adjustable Deadband, 15 A at 125/250/277 Vac Resistive
- Close Deadband, 5 A at 125/250 Vac Resistive
- High Ambient, 15 A at 125/250 Vac Resistive, Temperature -17.78° to 121° C (0° to 250° F)
Materials of Construction
Name Plate, Tag Material
- Stainless Steel, Paper ID Tag & Wire Attachment
Process Connection Material
Proof Pressure
- psi: 5 (kPa: 34.47, bar: 0.344)
Repeatability
- Set Point Repeatability: ± 1 % of Full Scale Range
Service
- Oxygen Service Cleaning, Alcohol Cleaning to Remove Residue from the Process Connection
Set Point - Decreasing
- bar: -1 to 0
- Inches Hg: -30 to 0
- kPa: -101.4 to 0
- psi: -14.7 to 0
Set Point - Increasing
- bar: -1 to 0
- Inches Hg: -30 to 0
- kPa: -101.4 to 0
- psi: -14.7 to 0
Shock
- Set Point Repeats after 15 G, 10 millisecond Duration
Storage Temperature
- -54° to 71° C (-65° to 160° F)
System Pressure
- bar: 0.35
- kPa: 34.5
- mbar: 345
- psi: 5
Vibration
- Set Point Repeats after 2.5 G, 5 to 500 CPS