Accuracy
- ± 1 % of Full Scale (The Effect of Non-Linearity, Hysteresis, Zero Point are included)
Approvals & Certifications
Burst Pressure
- psig: 7,975 (kPa: 54,985, to bar: 549.85)
Display
- 4-Digit LED: Red (0.35” H Digits)
Enclosure, Body Material
- 316L Stainless Steel Lower Body
- Fiberglass: Chemical Resistant Fiberglass Reinforced Plastic (PBT) Plastic Head
Loop Resistance
- > 10 kiloohms DPT-V
- ≤ 0.5k ohms DPT-A
Maximum System Pressure
- psig: 1,740 (kPa: 11,996, bar: 119.96)
NACE & NIST
- NIST Traceable Calibration Certificate
Output
- 0-10 Vdc: DPT-V
- 4-20 mA: DPT-A
Pressure Range
- bar: -1 to 68.9
- kPa: -101.3 to 68,948
- psig: -14.5 to 1,000
Temperature Range
- 0° to 80° C (32° to 176° F)
Wetted Materials
- 316L Stainless Steel Pressure Connection (13-8 PH for Ranges Above 150 psi)