8323 Pressure Transmitter

Brand: Burkert Fluid Control Systems
Does not ship to OH, United States

This pressure transmitter is designed to cover the majority of industrial applications in the field of industrial pressure measurement technology. High accuracy, compact design, robust construction and flexibility make this instrument universal and suitable for different measurement functions. 

For technical reasons the piezoresistive sensor element is used for measuring ranges psi: 0 to 232.1 (kPa: 0 to 1,600, bar: 0 to 16) and the thin film sensor element for the measuring range of psi: 362.6 (kPa: 2,500, bar: 25). Wetted parts are made of stainless steel and completely welded. Internal seal elements, which could restrict the choice of measuring materials, are excluded.
Features
  • Piezoresistive or thin film sensor element
  • Available with hygienic flush diaphragm
  • Housing and wetted parts in corrosion-resistant stainless steel
  • Standard signal 4-20 mA for connection to automation systems
  • Plug for quick installation and service

Specifications

Ambient Temperature Range

  • -20° to 80° C (-4° to 176° F)

Approvals & Certifications

  • CE
  • EU Directives
  • PED 2014/68/EU

BSP Connection

  • Flush Diaphragm Version: G 1” B Hygienic
  • Flush Diaphragm Version: G 1” B with O-Ring (Range up to 1.6 bar)
  • Flush Diaphragm Version: G 1/2” B with O-Ring (Range > 1.6 bar)
  • Standard Version: G 1/2” A According to DIN 16288

Burst Pressure

  • psi: 29.01 to 3,626 (kPa: 2 to 25,000, bar: 2 to 250)

Circuit Protection

  • Short Circuit Protected

Compensated Temperature

  • 0° to 80° C (32° to 176° F)

Electrical Connectors

  • 4-Pin Cable Plug According to EN 175301-803

Electrical Protection

  • Overvoltage Protection

Enclosure, Body Material

  • 316Ti Stainless Steel, 1.4571

Environmental Protection

  • IP65

Hysteresis

  • ≤ 0.1 % of Full Scale

Maximum System Pressure

  • psi: 14.5 to 1,160 (kPa: 100 to 8,000, bar: 1 to 80)

Measuring Error

  • Measurement Deviation: ≤ 0.25 % of Full Scale (Best Fit Calibration, BFSL)
  • Measurement Deviation: ≤ 0.5 % of Full Scale (2-Point Calibration)

Mounting Position

  • Vertical

Output

  • 4-20 mA, 2-Wire

Power Supply

  • 10-30 Vdc

Pressure Range

  • bar: 0 to 25
  • kPa: 0 to 2,500
  • psi: 0 to 362.6

Process Temperature

  • Hygienic Flush Diaphragm Version: -20° to 150° C (-4° to 302° F)
  • Standard Flush Diaphragm Version: -30° to 100° C (-22° to 212° F)
  • Standard Version: -20° to 100° C (-4° to 212° F)

Repeatability

  • ≤ 0.05 % of Full Scale

Response Time

  • ≤ 1 millisecond

Reverse Polarity Protection

  • Protected Against Reverse Polarity

Seat / Seal Material

  • Hygienic Flush Diaphragm Version (Seal): EPDM
  • Standard Flush Diaphragm Version (Seal): FKM

Span & Zero Adjustments

  • ± 10 %

Stability

  • ≤ 0.2 % of Full Scale / 1-Year

Storage Temperature

  • Hygienic Flush Diaphragm Version: -20° to 100° C (-4° to 212° F)
  • Standard Version, Standard Flush Diaphragm Version: -40° to 100° C (-40° to 212° F)

Temperature Coefficient

  • Average Tc of Zero (Flush Diaphragm Version): ≤ -0.2 to 0.3 % of Full Scale/10K
  • Average Tc of Zero (Standard Version), Average Tc of Span: ≤ 0.2 % of Full Scale/10K

Welded Connection

  • Flush Diaphragm Version: G 1” B Hygenic Weld-On Socket
  • Flush Diaphragm Version: G 1” B Weld-On Socket
  • Flush Diaphragm Version: G 1/2” B Weld-On Socket

Wetted Materials

  • Standard Version (1.4542 with bar: 25), Standard & Hygienic Flush Diaphragm Version: 316Ti Stainless Steel 1.4571

show more