8006 Mass Flow Meter
Brand: Burkert Fluid Control Systems
                Does not ship to OH, United States
            
    
The mass flow meter (MFM) type 8006 is suited for measuring the mass flow of high gas flows. The thermal inline sensor is located directly in the gas stream and therefore reaches very fast response times.
Type 8006 can optionally be calibrated for two different gases; the user can switch between these two gases. As electrical interfaces both, Analog standard signals and fieldbuses are available.
The MFM type 8006 is especially designed for use in harsh environments due to a low sensitivity to contamination and the high protection class.
                            Specifications
Accuracy
- ± 0.3 % of Full Scale after 15 minutes Warm-Up Time
 - ± 1.5 % of Reading after 15 minutes Warm-Up Time
 
Ambient Temperature Range
- -10° to 45° C (14° to 113° F)
 
Applications
- Harsh Environments
 
Approvals & Certifications
- CE
 
BSP Connection
- G 1" Female
 - G 1/2" Female
 - G 1/4" Female
 - G 3/4" Female
 - G 3/8" Female
 
Communication
- CAN Bus
 - DeviceNet Bus
 - Digital
 - FOUNDATION Fieldbus, CANopen
 - Modbus RTU
 - PROFIBUS DP
 - RS-232
 - RS-422
 - RS-485
 - USB
 
Consumption
- Power Consumption Fieldbus: 4-12.5 W (According to Version)
 - Power Consumption: 3.5-10 W
 
Electrical Connectors
- DeviceNet & CANopen: M12 Plug, 5-Pin
 - D-Sub 15-Pin Connector
 - PROFIBUS-DP, DeviceNet & CANopen & RS-485 Version Only: D-Sub 9-Pin Connector
 - PROFIBUS-DP: Socket M12 5-Pin
 - Socket M16, 8-Pin Round Connector
 
Electrical Contacts
- Normally Closed
 - Normally Open
 
Enclosure Finish
- Aluminum
 
Enclosure, Body Material
- Aluminum
 - Stainless Steel
 
Environmental Protection
- Typical of Protection: IP65
 
Flow Rate
- Nominal Flow Range: 20 to 2,500 LPM
 
Indication
- LED Indication for Power, Communication, Limit & Error
 
Media
- Air
 - Neutral Gasses
 
Mounting Position
- Horizontal
 - Vertical
 
NPT Connection
- 1" NPT Female
 - 1/2" NPT Female
 - 1/4" NPT Female
 - 3/4" NPT Female
 - 3/8" NPT Female
 
Operating Pressure
- Maximum
 
Operating Voltages
- 24 Vdc
 
Output
- Analog Communication: 0-10 V (Actual Flow)
 - Analog Communication: 0-20 mA (Actual Flow)
 - Analog Communication: 0-5 V (Actual Flow)
 - Analog Communication: 4-20 mA (Actual Flow)
 - Maximum
 
Output Load
- Maximum
 
Process Temperature
- -10° to 60° C (14° to 140° F) with Oxygen
 - Gas: -10° to 70° C (14° to 158° F)
 
Relay Output
- One Relay Output for RS-485 Version: 1 A at 25 V, 25 VA
 - Two Relay Outputs for Analog Signal & Fieldbus Version: 1 A at 60 V, 60 VA
 
Repeatability
- ± 0.1 % of Full Scale
 
Response Time
- < 500 ms
 
Seat / Seal Material
- Seal: EPDM
 - Seal: FKM
 
Sensor Circuit
- Residual Ripple: < 2 %
 
Sensor, Probe Style
- InLine
 
Tolerance
- Voltage: ± 10 %
 
Turndown
- 1:50
 
- Harsh Environments