RGS™ Self-Regulating Heating Cable
Brand: Thermon, IncRGS self-regulating heating cables are part of the Thermon SnoTrace™ family of snow and ice melting systems.
Designed and approved specifically for roof and gutter applications, RGS withstands direct exposure to harsh environmental conditions.
Due to its self-regulating feature, RGS cable will increase power when exposed to ice and snow. When the cable has cleared the area, the power output will decrease to reduce energy consumption.
Layout of RGS cable for a roof and gutter snow and ice melting system is easy.
The step-by-step design guide leads the reader through determining the heating requirements, selecting the cable spacing and establishing the number of heating circuits and accessories required to complete the SnoTrace RGS system.
Features- 1.3 mm2 (16 AWG) Nickel-Plated Copper Bus Wire
- E-Beam Cross-Linked Polyolefin Semiconductive Heating Matrix
- E-Beam Cross-Linked Polyolefin Primary Dielectric Insulation
- Tinned Copper Metallic Braid
- Abrasion Resistant Polyolefin Outer Jacket with UV Inhibitor
Displaying prices & availability for Ohio, United States 43201 in USD. Change location.
- Start-Up Temperature - 0°F
- Operating Voltage - 208 Vac
- Cable Sleeving - Fluoropolymer Overjacket
- Start-Up Temperature - 0°F
- Operating Voltage - 120 Vac
- Cable Sleeving - Fluoropolymer Overjacket
- Start-Up Temperature - 0°F
- Operating Voltage - 120 Vac
- Cable Sleeving - Polyolefin Overjacket
- Start-Up Temperature - 0°F
- Operating Voltage - 208 Vac
- Cable Sleeving - Polyolefin Overjacket
Specifications
Brand
Supply Voltage
- 110-120 or 208-277 Vac
Minimum Bend Radius
- 32 mm (1.25")
Nominal Power Output @ 0°C (32°F)
- In Snow & Ice: 39 W/m (12 W/ft)
- In Dry Air: 20 W/m (6 W/ft)
Approvals & Certifications
- CSA
- UL