8620 Multifunction Controller

Brand: Burkert Fluid Control Systems
Does not ship to VA, United States

The mxCONTROL multifunction controller, is a microprocessor controller designed to automate the control of process variables within a water treatment system (e.g. boiler, cooling tower or Reverse Osmosis system). Sophisticated electronics and state of the art control algorithms ensure that optimum process control is maintained at all times, with minimal operator intervention. 

The controller is capable of processing numerous combinations of Analog and digital in and outputs. Combined with an easy to read large graphic display backlight in three languages, EN, DE, FR. Other languages on demand. 

The controller is highly software based. It can easily be configured/parameterized using a PC tool and SD card or USB interface. 

Alternatively, the optional Ethernet interface can be used to configure and to parameterize the controller. Local manual parameterizing of the controller can also be achieved via the five soft-touch keys.
Features
  • Data and event logging
  • One controller hardware with dozens of configuration possibilities quickly downloaded via SD card (supplied) or via USB interface
  • Ethernet or modem communication with email or call event notification and numerous input/output control signals

Specifications

Approvals & Certifications

  • CE
  • EMC: EN 61000, EN 55011
  • IEC 68
  • UL (C,US): 61010-1 + CRN/CSA C22 No.61010-1

Battery Life

  • Battery Back-Up for Real-time Clock: Lithium Battery CR2032, Exchangeable, Approximately 10-Years Service Life

Cable Entry

  • Cable Gland & Cable (Hardware Version 1 & 2): 1 x M32 (PG21) & 5 to 6 mm Cable Diameter (5 Times)
  • Cable Gland & Cable (Hardware Version 1): 9 x M16 (PG9) & 5 to 6.5 mm Cable Diameter
  • Cable Gland & Cable (Hardware Version 2): 2 x M16 (PG9) & 6 to 9.5 mm Cable Diameter
  • Cable Gland & Cable (Hardware Version 2): 3 x M20 (PG13) & 9 to 13.5 mm Cable Diameter
  • Cable Gland & Cable (Hardware Version 2): 4 x M16 (PG9) & 5 to 6.5 mm Cable Diameter

Circuit Protection

  • Overload Protection
  • Short Circuit Protected

Configuration

  • Up/Download of Configuration Data & Parameter: SD Card
  • Up/Download of Configuration Data & Parameter: USB

Consumption

  • Power Consumption (of MxControl Device): 35 W, Max.
  • Total Power Consumption (Using the Internal Power Distribution): 1,100 W, Max.
  • Total Power Consumption (Using the Internal Power Distribution): 2,400 W, Max.

Current

  • Inrush Current (Typically) - Cold Start: 30 A at 230 Vac

Display

  • Graphic Display, Large & Backlighted 128 x 64 Dots, Two Colored (Blue & White)

Electrical Connectors

  • Hardware Version 1: Screw Terminals
  • Hardware Version 2: Spring Typical Terminals
  • Instrumentations Supply (Hardware Version 1): Grid 3.81 mm, for Wire Gauges 0.14 to 1.0 / 1.5 mm² (AWG 26 to 16)
  • Instrumentations Supply (Hardware Version 2): Grid 3.5 mm, for Wire Gauges 0.2 to 1.5 / 1.5 mm² (AWG 24 to 16)
  • Power Supply (Hardware Version 1): Grid 5.08 mm, for Wire Gauges 0.14 to 1.5 / 2.5 mm² (AWG 26 to 14)
  • Power Supply (Hardware Version 2): Grid 5.0 mm, for Wire Gauges 0.2 to 2.5 / 4.0 mm² (AWG 24 to 12)

Enclosure, Body Material

  • Polycarbonate (PC) (UL 94) with Transparent Door & Key

Environmental Protection

  • IP65
  • IP66
  • NEMA 4X

Frequency

  • 2 kHz, Max.
  • Transistor Output: 2,200 Hz, Max.

Input

  • 4-20 mA
  • Logical Value ON/OFF Input - 0 or Low: 0-4.5 V
  • Logical Value ON/OFF Input - 1 or HIGH: 13-35 V
  • Total Input Current Iᵢₙ (Using the Internal Power Distribution): 10 A, Max.

Interface Connection

  • Ethernet
  • USB Slave Interface: USB Interface for PC Communication

Load Resistance

  • 4-20 mA Analog Output Characteristics: 500 ohms, Max.

Measuring Error

  • Measuring Error Frequency: Max.
  • Measuring Error of 4-20 mA Input: < 0.2 % of Full Scale
  • Measuring Error Pt100 Input: ± 0.25 K (3-Wire Connection & Software Compensated Wire Resistance Required)

Mounting

  • Wall Mounted

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Output

  • 4-20 mA
  • Instrumentation Supply for Sensor/Transistor Output: Max.
  • Switching Capacity Each, Max.
  • Total Output Current Iₒᵤₜ (Using the Internal Power Distribution): < 10 A (Including Device Power Consumption of 35 W)
  • Transistor Output: 24 Vdc

Power Supply

  • 100-240 Vac at 50/60 Hz
  • Instrumentation Supply for Sensor/Transistor Output: 24 Vdc ± 5 %

Relay Output

  • 2,500 VA (AC)
  • 250 Vac/dc at 10 A, Max.
  • Maximum

Resistance

  • Input Resistance of 4-20 mA Input: 300 ohms, Max.
  • Input Resistance of ON/OFF Input: ≥ 20 kiloohms

Resolution

  • 4-20 mA Analog Output Characteristics: 10-bits (Effective > 9-bits)

RTD Type

  • Pt100

Sample Rate

  • Sample Period: Approximately 100 milliseconds (More Than 4 Active Control Loops)
  • Sample Period: Approximately 50 milliseconds (with 1 to 4 Active Control Loops)

Stability

  • Thermal Stability (Cable Material): 105° C (221° F) for Cables at Power Supply Part
  • Thermal Stability (Cable Material): 80° C (176° F) for Cables at Instrumentation Supply Part

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

Switch Type

  • Relay Output: SPDT
  • Transistor Output: PNP Transistor

Temperature Range

  • Range of Pt100 Input: -20° to 150° C (-4° to 302° F)

show more