8035-Digital Flow Transmitter
Brand: Burkert Fluid Control SystemsDoes not ship to OH, United States
The flow transmitter is specially designed for use in neutral, slightly aggressive, solid free liquids. The transmitter is made up of a compact fitting with paddle wheel (S030) and an electronic module (SE35) quickly and easily connected together by a Quarter-Turn.
The Burkert designed fitting system ensures simple installation of the sensors into all pipes from DN06 to DN65.
The device is available in different models:
- Flow transmitter with standard output signal
- Battery powered
- Compact version for DN06 to DN65
- Displays both flow rate and volume (with two totalizers)
- Automatic calibration: Teach-In
- Simulation: All output signals provided without the need for real flow
Specifications
Accuracy
- 4-20 mA Output Uncertainty: ± 1 %
Ambient Temperature Range
- Operation & Storage: 0° to 50° C (32° to 122° F) (115/230 Vac Version)
- Operation & Storage: 0° to 55° C (32° to 131° F) (Batteries Version)
- Operation & Storage: 0° to 60° C (32° to 140° F) (12-36 Vdc)
- UL Recognized: 0° to 40° C (32° to 104° F)
Approvals & Certifications
- Safety: EN 61010-1
- CE
- EMC: EN 61000-6-2, EN 61000-6-3
- PED 2006/95/CE
- UL (C,US): UL 61010-1 + CAN/CSA C22.2 No. 61010-1
Bearing Material
- Ceramics
Consumption
- Current (Transmitter with Relays): ≤ 70 mA at 12 Vdc
- Current (Transmitter without Relay): ≤ 25 mA at 12 Vdc
Cover Material
- Polycarbonate (PC)
Current
- Fuse 125 mA - Max.
Diameter
- Pipe: 1/4 to 2-1/2" (DN06 to DN 65)
Display
- 15 x 60 mm, 8-Digit LCD, Alphanumeric, 15-Segments, 9 mm High
Electrical Connectors
- 50 metres, Max.
- Battery Version: Cable Glands M20 x 1.5
- Battery Version: Cable Plug EN 175301-803
- Shielded Cable with 1.5 mm², Max.
Enclosure, Body Material
- Polycarbonate (PC)
Environmental Protection
- IP65
Gland Material
- Polyamide (PA)
Humidity
- ≤ 80 % RH, Non-Condensing
- UL Recognized: Max.
Indication
- LED
Linearity
- ± 0.5 % of Full Scale
Loop Impedance
- 50 ohms at 12 Vdc, Max.
- 600 ohms at 24 Vdc, Max.
- 800 ohms with a 115/230 Vac, Max.
- 900 ohms at 30 Vdc, Max.
Materials of Construction
- Front Panel Foil: Polyester
- Lid: Polycarbonate (PC)
Measuring Error
- Measurement Deviation (Standard K-factor): ± 2.5 % of Reading
- Measurement Deviation (Teach-In): ± 1 % of Reading
Measuring Range
- 0.3 to 10 m/sec
Nut & Bolt Material
- Nut: Polycarbonate (PC)
Output
- Pulse: 2.5 Vdc at 100 mA
- Pulse: 5-36 Vdc
- Standard Signal Version (3-Wire with Relays, 2-Wire without Relay): 4-20 mA
Pipe Connection
- DN 15 Pipe
- DN 20 Pipe
- DN 25 Pipe
- DN 32 Pipe
- DN 40 Pipe
- DN 50 Pipe
- DN 65 Pipe
Plug Material
- Cable Plug: Polyamide (PA)
Power
- 3 VA
Power Supply
- Battery Indicator/Totalizer Version: 4 x 1.5 Vdc Non-Rechargeable Alkaline AA Batteries
- Standard Signal Version: 115-230 Vac at 50/60 Hz
- Standard Signal Version: 12-36 Vdc ± 10 %
Pressure Range
- bar: 0 to 16
- kPa: 0 to 1,600
- psi: 0 to 232.16
Process Temperature
- PP: 0° to 80° C (32° to 176° F)
- PVC: 0° to 50° C (32° to 122° F)
- PVDF, Brass or Stainless Steel: -15° to 100° C (5° to 212° F)
Relay Output
- 2 Relays
- 230 Vac / 3 A
- Resistive Load: 40 Vdc / 3 A
- UL Recognized: 30 Vac
- UL Recognized: 42 V Peam, Max.
- UL Recognized: 60 Vdc, Max.
Repeatability
- ± 0.4 % of Reading
Reverse Polarity Protection
- Yes
Screw Material
- Stainless Steel
Seat / Seal Material
- Seal: EPDM
- Seal: FKM
Shock
- EN 60068-2-27
Supply Voltage
- 27 Vdc Regulated
Tri-Clamp Connection
- DN 15 Tri-Clamp
- DN 20 Tri-Clamp
- DN 25 Tri-Clamp
- DN 32 Tri-Clamp
- DN 40 Tri-Clamp
- DN 50 Tri-Clamp
- DN 65 Tri-Clamp
Vibration
- EN 60068-2-6
Viscosity
- 300 cSt, Max.
Welded Connection
- DN 15 Weld End
- DN 20 Weld End
- DN 25 Weld End
- DN 32 Weld End
- DN 40 Weld End
- DN 50 Weld End
- DN 65 Weld End
Wetted Materials
- Axis: Ceramics
- Fitting, Sensor Armature, Paddle-wheel: PVDF
- Fitting, Sensor Armature: 316L Stainless Steel, 1.4404
- Fitting, Sensor Armature: Brass
- Fitting, Sensor Armature: Polypropylene (PP)
- Fitting, Sensor Armature: PVC