Ambient Temperature Range
- 55° C (131° F) - Max.
- Block Mounting: -30° to 50° C (-22° to 122° F) - ATEX/IECEx Version
- Single Mounting: -30° to 60° C (-22° to 140° F) - ATEX/IECEx Version
Approvals & Certifications
- Air Pressure Quality: ISO 8573-1: 2010, Class 7.4.4
- CE
- Coil: IECEx PTB 14.0049 x (II 2 G Ex Mb IIC T5 Gb, II 2D Ex Mb IIIC T 100° C Db), Junction Box: IECEx EPS 16.0021 x (II 2 G EX Eb Mb IIC T5 Gb, II 2D EX Mb Tb IIIC T100° C Db)
- Coil: PTB 14-ATEX-2023 x (II 2 G Ex Mb IIC T5 Gb, II 2D Ex Mb IIIC T 100° C Db), Junction Box: EPS 16-ATEX-1046 x (II 2 G EX Eb Mb IIC T5 Gb, II 2D EX Mb Tb IIIC T100° C Db)
Consumption
- Power Consumption (Version with Vac): 11 VA (Inrush)
- Power Consumption (Version with Vac): 6 VA (Hold)
- Power Consumption (Version with Vdc): 2 W
Electrical Connectors
- 3 metres Cable, Moulded - ATEX/IECEx Version
- Junction Box (without Fuse), Moulded - ATEX/IECEx Version
- Tag Connectors According to DIN EN 175301-803 (Previously DIN 43650) Form A for Cable Plug Typical 2508
Flow Rate
- QNn-Value Air: 200 L/minute
Materials of Construction
- Coil Material: Epoxy
- Coil Material: Polyamide
Media
- Lubricated Compressed Air
- Neutral Medium
- Non-Lubricated Compressed Air
Mounting Position
- Preferably with Actuator Upright
Operating Voltages
- 24 Vdc
- 24-230 V at 50/60 Hz
- 24-230 VUC - ATEX/IECEx Version
Power
- Coil Power: 3 W - ATEX/IECEx Version
Pressure Range
- psi: 36.26 to 145 (kPa: 250 to 1,000, bar: 2.5 to 10)
Process Temperature
- -10° to 60° C (14° to 140° F)
Response Time
- Closing: 20 milliseconds (Pressure Drop 100 to 10 %)
- Opening: 30 milliseconds (Pressure Rise 0 to 90 %)