BSX™ Self Regulating Heating Cable

Brand: Thermon, Inc.

BSX self-regulating heating cables are designed to provide freeze protection or process temperature maintenance to metallic and nonmetallic piping, tanks and equipment.

The heat output of BSX cable varies in response to the surrounding conditions along the entire length of a circuit.

Whenever the heat loss of the insulated pipe, tank or equipment increases (as ambient temperature drops), the heat output of the cable increases.

Conversely, when the heat loss decreases (as the ambient temperature rises or product flows), the cable reacts by reducing its heat output.

BSX cables are approved for use in ordinary (non-classified) areas and hazardous (classified) areas.
Features
  • Freeze protection
  • Low process temperature maintenance
  • No steam clean
  • Certified for use in ordinary (non-classified) areas and in potentially explosive atmospheres

32 models matching criteria
D1-BSX 5-1-FOJ
  • Supply Voltage - 120 Vac Nominal
  • Power Output - 5 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
BSX 8-2-FOJ
  • Supply Voltage - 240 Vac Nominal
  • Power Output - 8 W/ft
  • Approvals - None
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
D1-BSX 8-2-OJ
  • Supply Voltage - 240 Vac Nominal
  • Power Output - 8 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
BSX 5-2-OJ
  • Supply Voltage - 240 Vac Nominal
  • Power Output - 5 W/ft
  • Approvals - None
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
BSX 3-2-FOJ
  • Supply Voltage - 240 Vac Nominal
  • Power Output - 3 W/ft
  • Approvals - None
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
D1-BSX 10-1-OJ
  • Supply Voltage - 120 Vac Nominal
  • Power Output - 10 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
BSX 5-1-FOJ
  • Supply Voltage - 120 Vac Nominal
  • Power Output - 5 W/ft
  • Approvals - None
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
D1-BSX 5-2-OJ
  • Supply Voltage - 240 Vac Nominal
  • Power Output - 5 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
D1-BSX 8-1-FOJ
  • Supply Voltage - 120 Vac Nominal
  • Power Output - 8 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
D1-BSX 10-2-OJ
  • Supply Voltage - 240 Vac Nominal
  • Power Output - 10 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days

Specifications

Watt Densities

  • 3 w/ft @ 50° F
  • 5 w/ft @ 50° F
  • 8 w/ft @ 50° F
  • 10 w/ft @ 50° F

Supply Voltages

  • 110-220 V
  • 208-277 Vac

Temperature Range

  • -51° C to 85° C
  • -60° F to 185° F
Show More