HPT™ Power Limiting Heating Cable

Brand: Thermon, Inc.

High performance HPT power-limiting heating cables are designed specifically for process temperature maintenance or freeze protection where high maintain temperatures or high temperature exposure is required.

A coiled resistor alloy heating element provides the power limiting feature of HPT. This PTC (Positive Temperature Coefficient) characteristic decreases the cable’s power output as the heat-traced product temperature increases and allows the cable to be overlapped during installation.

The composite construction of the heating element and fiber substrate, plus an additional fiber cushion layer, provide an exceptionally durable high performance heating cable.

HPT cables are approved for use in ordinary (non-classified) areas, hazardous (classified) areas, and Zone 1 and 2 classified areas.
Features
  • Medium to high process temperature maintenance
  • Steam clean/purge
  • Certified for use in ordinary (non-classified) areas and in potentially explosive atmospheres

32 models matching criteria
HPT 15-1-OJ
  • Voltage Rating - 120 Vac Nominal
  • Power Output - 15 W/ft
  • Approvals - None
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
HPT 20-1-FOJ
  • Voltage Rating - 120 Vac Nominal
  • Power Output - 20 W/ft
  • Approvals - None
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
HPT 20-1-OJ
  • Voltage Rating - 120 Vac Nominal
  • Power Output - 20 W/ft
  • Approvals - None
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
D1- HPT 10-2-FOJ
  • Voltage Rating - 240 Vac Nominal
  • Power Output - 10 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
D1- HPT 15-1-FOJ
  • Voltage Rating - 120 Vac Nominal
  • Power Output - 15 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
D1- HPT 5-2-OJ
  • Voltage Rating - 240 Vac Nominal
  • Power Output - 5 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
D1- HPT 10-1-OJ
  • Voltage Rating - 120 Vac Nominal
  • Power Output - 10 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
HPT 5-1-FOJ
  • Voltage Rating - 120 Vac Nominal
  • Power Output - 5 W/ft
  • Approvals - None
  • Cable Sleeving - Fluoropolymer Overjacket
25 - 45 days
D1- HPT 20-2-OJ
  • Voltage Rating - 240 Vac Nominal
  • Power Output - 20 W/ft
  • Approvals - Division 1 Hazardous Areas
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days
HPT 10-1-OJ
  • Voltage Rating - 120 Vac Nominal
  • Power Output - 10 W/ft
  • Approvals - None
  • Cable Sleeving - Polyolefin Overjacket
25 - 45 days

Specifications

Watt Densities

  • 5 w/ft @ 50° F
  • 10 w/ft @ 50° F
  • 15 w/ft @ 50° F
  • 20 w/ft @ 50° F

Voltage Output

  • 120/240 Vac Nominal

Maximum Maitenance Temperature

  • HPT 5: 410° F
  • HPT 10: 374° F
  • HPT 15: 347° F
  • HPT 20: 302° F

Minimum Bend Radius

  • 32 mm @ -60° F
  • 10 mm @ 5° F

Show More