Ambient Temperature Range

  • Operating & Storage: -20° to 40° C (-4° to 104° F) - SE56 Blind
  • Operating & Storage: -20° to 60° C (-4° to 140° F) - SE56 Standard with Display
  • Operating: -10° to 50° C (14° to 122° F) - SE56 Basic
  • Storage: -20° to 50° C (-4° to 122° F) - SE56 Basic

Approvals & Certifications

  • CE
  • EU

Cable Length

  • 20 metres, Max.

Communication

  • HART - SE56 Standard with Display
  • PROFIBUS DP - SE56 Standard with Display & SE56 Blind
  • RS-232 - SE56 Standard with Display
  • RS-485

Consumption

  • Power: 10 W, Max.
  • Power: 25 VA, Max.
  • Power: 6 W, Max.

Cover Material

  • Polyphenylene Sulfide (PPS) - SE56 Blind

Display

  • Alphanumeric Display 2 Lines x 16-Characters, without Back Light - SE56 Basic
  • Graphic Display 8 Lines x 16-Characters, 128 x 64 Pixels with Back Light - SE56 Standard with Display

Electrical Connectors

  • 2 Cable Glands PG9 - SE56 Blind
  • 3 Cable Glands PG11 - SE56 Basic
  • 6 Cable Glands PG11 - SE56 Standard with Display

Enclosure, Body Material

  • 304 Stainless Steel Electro-Polish - SE56 Standard with Display
  • Die Casting Aluminum - SE56 Standard with Display
  • Nylon
  • Polyamide 6 (PA6) with Glass Fiber - SE56 Basic
  • Stainless Steel - Electronics SE56 Blind

Environmental Protection

  • IP65 - SE56 Basic
  • IP67 - SE56 Standard with Display & SE56 Blind

Frequency

  • 1,250 Hz

Function

  • Batch Function - SE56 Standard with Display & SE56 Blind
  • Bi-Directional Measure
  • Diagnostic Function
  • Dual Measurement Range - SE56 Standard with Display
  • Empty Pipe Detection
  • Plug in (Protected Plug for Connection to PC or Hand Terminal) - SE56 Basic
  • Remote Configuration (For Connection to PC or Hand Terminal through Remote Configuration Tool Kit) - SE56 Standard with Display & SE56 Blind

Humidity

  • ≤ 85 % Relative Humidity, Non-Condensing

Isolation

  • Galvanically Isolated (All the Input/Outputs are Galvanically Isolated from Power Supply)

Load Resistance

  • 1,000 ohms - SE56 Standard with Display
  • 800 ohms Passive - SE56 Blind & SE56 Basic

Mounting

  • Wall Mounted

Output

  • 4-20 mA
  • Pulse: 100 mA
  • Pulse: 40 Vdc

Output Format

  • Open Collector

Power Supply

  • 12-60 Vdc - SE56 Basic
  • 20-30 Vdc - SE56 Blind
  • 90-265 Vac - SE56 Standard with Display (44 to 66 Hz) & SE56 Basic

Repeatability

  • ± 0.1 % of Reading - SE56 Standard with Display & SE56 Blind
  • ± 0.2 % of Reading - SE56 Basic

Seat / Seal Material

  • Seal: EPDM - SE56 Blind

Tolerance

  • Flow Rate (Volume): ± 0.05 % of Reading - SE56 Standard with Display
  • Flow Rate (Volume): ± 0.1 % of Reading - SE56 Basic
  • Output 4-20 mA, Frequency Output: ± 0.08 % of Reading - SE56 Standard with Display
  • Output 4-20 mA, Frequency Output: ± 0.12 % of Reading - SE56 Basic
show more